Many of our customers come to our Non-Rechargeable Batteries collection for reliable, long-lasting primary power. They’re looking for AED batteries (Zoll, Defibtech, Welch Allyn, Yuwell), 3.6V lithium cells for PLCs, CNC systems and industrial robots, and high-energy packs such as the SAFT BA-5699/U for two-way radios. In these applications, a weak or damaged cell can mean a failed device or a safety risk. So before any primary battery leaves our warehouse, we put it through a structured testing and inspection process. In this article I’ll walk you through how we do it, and then explain how you should handle the batteries once they reach you.

How We Test Before We Ship

Step 1: Incoming Inspection and Traceability

Testing begins when stock arrives at our warehouse. Every batch is logged with its manufacturer, model, lot number and date code. We check:

  • Labeling: we confirm the chemistry, nominal voltage, capacity, model number and polarity markings match the specification. For AED and PLC batteries, a close part number isn’t good enough, so we verify the full model against the product listing.
  • Date codes and expiry: shelf life matters for primary cells, so we manage inventory first-in, first-out (FIFO). We don’t ship stock that is close to its limit.
  • Physical condition: we look for dents, swelling, corrosion, electrolyte residue, damaged sleeves, and damaged connectors or plugs. If we find any sign of leakage, the whole batch is quarantined.
  • Dimensions: we measure the size against the datasheet, because poor fit is a common cause of contact problems in devices.

Step 2: Electrical Testing on Sampled Units

We pull samples from each lot following a recognized sampling approach such as ANSI/ASQ Z1.4 (ISO 2859-1), with sample size depending on the lot size. On those samples we run:

  • Open-circuit voltage (OCV): a quick check that the cell is within the expected range for its chemistry, for example around 3.6V for the ER-series lithium cells used in PLC and robot applications. We treat this as a first screen only, since OCV alone can hide a partly depleted cell.
  • Closed-circuit voltage (CCV) under load: we apply a defined load and record the voltage. This shows how the cell will behave in a real device, which is especially important for AED packs and high-energy radio batteries.
  • Internal resistance: a high reading tells us the cell may be aged or defective and could fail under demanding loads.
  • Capacity sampling: for selected lots, we discharge sample cells under controlled conditions and compare the result with the rated capacity, following the methods in the IEC 60086 series. This test consumes the sample, so we use it selectively rather than on every unit.

Step 3: Chemistry-Specific Checks

We don’t test every battery the same way, because each chemistry has different weak points:

  • Lithium thionyl chloride (Li-SOCl₂), such as the ER6V, ER17/50 and ER17500V: these cells can form a passivation layer during storage, which causes a temporary voltage delay at first load. We run a load or pulse test to confirm the cell recovers normally.
  • Lithium manganese dioxide (LiMnO₂), such as AED batteries like the Zoll AED 3 and Yuwell HeartOn A10, and the B9508 PLC cell: we focus on voltage under load, the condition of the case, connectors and leads, and the date information.
  • Lithium sulfur dioxide (Li-SO₂), such as the SAFT BA-5699/U: we inspect the case closely for damage, and we apply extra care in handling and packing.

Any lot that falls outside specification is held back, and we contact the manufacturer rather than ship it.

Step 4: Packaging and Transport Compliance

Passing the electrical tests isn’t enough, so before shipping we also check packaging and compliance:

  • Classification: lithium metal batteries are dangerous goods (UN3090 and UN3091), and the cells must have passed UN 38.3 testing. We confirm the test documentation and apply the correct labels and paperwork for the shipping method.
  • Short-circuit protection: terminals, connectors and plugs are protected with blister packs, sleeves or non-conductive separators, so cells can never touch each other or metal objects.
  • Secure packing: cells are packed so they can’t shift or be crushed in transit.
  • Final check before sealing: we verify the model, quantity and date code against the order, and keep batch records so we can trace any issue later.

This process lets us ship batteries that are fresh, within specification and packed to arrive safely.

What You Should Do When Your Batteries Arrive

Even a well-tested battery can be damaged by poor handling, so here is what we recommend.

1. Inspect on Arrival

  • Check the carton for crushing, moisture or other damage.
  • Confirm the model, voltage, capacity and quantity match your order and your device. For AED, PLC and robot batteries, check the exact part number against your equipment manual.
  • Check the date code or expiry date.
  • If you see leakage, swelling, discoloration or a chemical smell, don’t use the battery. Keep it away from heat in a non-conductive container, and contact us with photos and the lot or date code.

2. Store Them Properly

  • Keep batteries in their original packaging until use.
  • Store them in a cool, dry place away from direct sunlight and heat sources.
  • Never store loose batteries with coins, keys or other metal objects, which can cause a short circuit.
  • Don’t mix different chemistries, brands or ages in the same container.
  • For spares of critical equipment, label each one with its receiving date and use the oldest first.

3. Install Them Correctly

  • Use the exact type your device specifies. Similar-looking batteries are not always interchangeable, and the wrong voltage or chemistry can damage equipment.
  • Check polarity (+/−) and connector orientation before inserting, and make sure plugs seat fully.
  • Clean the contacts with a dry, lint-free cloth if you see dust or residue.
  • Replace all batteries at the same time in multi-cell devices. Never mix old with new, or different brands or chemistries.
  • For AED batteries, follow your device manual, confirm the device’s self-test or status indicator shows it is ready after installation, and replace the battery before its expiry date.
  • For PLC, CNC and robot backup batteries, check the manual first, because some systems must stay powered while you swap the battery to avoid losing memory or position data.
  • For Li-SOCl₂ cells stored for a long time, a brief voltage dip at first use can be normal. Check the manufacturer’s datasheet before assuming the cell is faulty.

4. Use Them Safely

  • Never recharge a non-rechargeable battery. It can cause gas build-up, leakage, fire or rupture.
  • Don’t heat, crush, puncture, disassemble or burn batteries. For high-energy packs such as the BA-5699/U, use them only in the equipment they are specified for and in a ventilated area.
  • Remove batteries from devices that will be stored for a long time.
  • Remove depleted batteries promptly, because fully discharged cells are more likely to leak.
  • Keep batteries away from children and pets. If a battery is swallowed, treat it as a medical emergency and seek help immediately.

5. Dispose of Them Responsibly

  • Cover the terminals of used lithium batteries with non-conductive tape.
  • Don’t put them in household trash. Use a local battery recycling or hazardous-waste collection point, and follow the regulations in your region.

Quick Checklist

  • Exact model, voltage and capacity match the device
  • No damage or leakage on the packaging or cells
  • Date code and expiry checked
  • Stored cool, dry and in original packaging
  • Polarity and connector checked, contacts clean
  • All cells replaced together, none mixed
  • Never recharged, heated or disassembled
  • Used cells recycled with terminals taped

Final Thoughts

For us, quality control isn’t a single test. It’s a chain of checks from receiving to packing, and we want to make sure that chain doesn’t break once the batteries are in your hands. If you have any question about a battery you’ve received, send us the model, lot or date code and a few photos at order@storeshoppe.com, and our team will help you resolve it. Our orders also come with free shipping, a one-year warranty and free returns within 30 days.